UEi C157 Eagle 3X Combustion Analyzer

  • Sale
  • Regular price $1,914.95


Description

UEi C157 Eagle 3X Combustion Analyzer

The UEi C157 Eagle 3X Combustion Analyzer eliminates a significant hassle experienced by HVAC contractors who use combustion analyzers - the annual cost and associated down time of replacing the O2 sensor. With the C157, the electro-chemical O2 sensor is replaced with the EOS Technology CO2 sensor which calculates the O2 level based on the CO2 concentration. This CO2 sensor has no physical contact with the gas, so there is no deterioration of the sensor over time. The exclusive CO2 sensor has a an unmatched industry-leading life expectancy of 10 years. The Eagle 3X also offers an Xtended Life carbon monoxide sensor which has a life expectancy of 5 years, a lengthy life in terms of CO sensors. Reducing the sensor replacement frequency helps to minimize the user's cost of ownership to just the CO sensor calibration. The sensor can detect CO levels as low as 1 ppm.

Features

The UEi C157 Eagle 3X Combustion Analyzer measures carbon dioxide (CO2), carbon monoxide (CO), inlet and flue temperatures, differential pressures and nitric oxide (NO). From these measurements the following can be calculated; oxygen (O2), net temperature, combustion efficiency, excess air, differential temperature (T1-T2) and differential pressure (P1-P2). The pre-programmed fuels include, natural gas, propane, heavy and light oil, bio fuel and wood.

  • Worklight
  • 4 line backlit LCD display
  • 179 memory positions
  • User customizable parameters view
  • Infrared printer port for individual report printouts
  • Real-time clock
  • DMM style rotary selector
  • Protective boot with integral magnet

Warranty Information

The UEi C157 Eagle 3X Combustion Analyzer comes with a 5 year limited warranty, including the CO and CO2 sensors.

Product Specs
Temperature Measurements
Parameter Range Resolution Accuracy
Flue Temperature 20 to 2400 °F (-29 to 1315 °C) 0.1 °F/°C ±(0.3% reading + 3.6 °F (2 °C))
Inlet Temperature (Probe - T2) 20 to 2400 °F (-29 to 1315 °C) 0.1 °F/°C ±(0.3% reading + 3.6 °F (2 °C))
Inlet Temperature (ambient) 32 to 112 °F (0 to 50 °C) 0.1 °F/°C ±(0.3% reading + 3.6 °F (2 °C))
Net Temperature (∆T)
(Calculated value)
20 to 2400 °F (-29 to 1315 °C) 0.1 °F/°C ±(0.3% reading + 1.8 °F (1 °C))
Gas Measurements
Parameter Range Resolution Accuracy
Carbon Monoxide (CO)
0 to 2000 ppm
1 ppm
±10 ppm <100 ppm
±5% reading >100 ppm
Carbon Dioxide (CO2) 0 to 20% 0.1% ±2%
Nitric Oxide (NO1)
0 to 100 ppm
±2 ppm <30 ppm
±5 ppm <100 ppm
Calculations
Parameter Range Resolution Accuracy
Oxygen (O2) 0 to 21% 0.1% ±0.3%
Efficiency 0 to 99.9% 0.1% ±3.0%
Excess Air 0 to 250% 0.1% ±3.0%
CO/CO2 Ratio 0 to 0.999 0.001 ±5% reading
Pressure
Range Accuracy Resolution
±0.08” wc (±0.2mBar) ±0.002” wc (±0.005mBar)
0.001” wc <9.999” wc
0.01” wc >10.00” wc
0.001mBar <24.999mBar
0.01mBar >25 mBar
±0.4” wc (±1mBar) ±0.01” wc (±0.03mBar)
±32” wc (±80mBar) ±3% reading
Includes
  • UEi C157 Eagle 3X Combustion Analyzer
  • Flue Probe
  • Inlet tube/probe connector
  • Particle Filter
  • Hard Case
  • AC Adapter
  • Quick Start Guide
  • Owners Manual
Shipping

Free Shipping

Returns

Our policy lasts 30 days. If 30 days have gone by since you received purchase, unfortunately we can’t offer you a refund or exchange.

To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.