UEi C157 Eagle 3X Combustion Analyzer Oil Kit with Printer

  • Sale
  • Regular price $2,429.95


Description

UEi C157 Eagle 3X Combustion Analyzer Oil Kit with Printer

The Eagle 3X Combustion & System Analyzer eliminates the number onehassle experienced by HVAC contractors- the annual cost and down time of replacingthe O2 sensor. This new technology for combustion analysis replaces the everydayelectro-chemical O2 sensor with the EOS Technology CO2 sensor, lowering the costof ownership.

The new EOS CO2 sensor takes direct CO2 measurements and calculates the O2 level.This CO2 sensor has no physical contact with the gas, so there is no deterioration of thesensor over time. This exclusive EOS sensor has a 5 year limited warranty and anunmatched industry-leading life expectancy of 10 years!

The Eagle 3X also offers a new Xtended Life CO Sensor, which has a life expectancy of5 years and is backed by a 5 year limited warranty. Reducing the sensor's replacementfrequency helps to minimize the analyzer's cost of ownership to just the CO sensor calibration.


Measures:
- CO2 (EOS Technology)
- CO (Long Life Sensor)
- Inlet Temp/Flue Temp
- Hi-Res Differential Manometer (select 0.01"/0.001"wc)
- NO

Calculates:
- O2
- Net Temp
- Efficiency
- Excess Air
- Differential Temp (T1-T2)
- Differential Pressure (P1-P2)

PreProgrammed Fuels:
- Natural Gas
- Propane
- Heavy Oil
- Light Oil
- Bio Fuel
- Wood

Features:
- Gas Zero
- High level CO alarm
- CO data logger
- Heat exchanger test
- Worklight
- 4 line backlit LCD display
- 179 memory positions
- User customizable auxiliary screen
- User programmable headers
- Individual report printouts
- Time and date stamp
- Rotary style selector
- Protective boot w/integral magnet
- Real time clock
- CO readings as low as 1 ppm
- Infrared printer port
- Low battery indicator
- Field replaceable sensors
- 5 year limited warranty (including sensor)

Product Specs
Temperature Measurements
Parameter Range Resolution Accuracy
Flue Temperature 20 to 2400 °F (-29 to 1315 °C) 0.1 °F/°C ±(0.3% reading + 3.6 °F (2 °C))
Inlet Temperature (Probe - T2) 20 to 2400 °F (-29 to 1315 °C) 0.1 °F/°C ±(0.3% reading + 3.6 °F (2 °C))
Inlet Temperature (ambient) 32 to 112 °F (0 to 50 °C) 0.1 °F/°C ±(0.3% reading + 3.6 °F (2 °C))
Net Temperature (∆T)
(Calculated value)
20 to 2400 °F (-29 to 1315 °C) 0.1 °F/°C ±(0.3% reading + 1.8 °F (1 °C))
Gas Measurements
Parameter Range Resolution Accuracy
Carbon Monoxide (CO)
0 to 2000 ppm
1 ppm
±10 ppm <100 ppm
±5% reading >100 ppm
Carbon Dioxide (CO2) 0 to 20% 0.1% ±2%
Nitric Oxide (NO1)
0 to 100 ppm
±2 ppm <30 ppm
±5 ppm <100 ppm
Calculations
Parameter Range Resolution Accuracy
Oxygen (O2) 0 to 21% 0.1% ±0.3%
Efficiency 0 to 99.9% 0.1% ±3.0%
Excess Air 0 to 250% 0.1% ±3.0%
CO/CO2 Ratio 0 to 0.999 0.001 ±5% reading
Pressure
Range Accuracy Resolution
±0.08” wc (±0.2mBar) ±0.002” wc (±0.005mBar)
0.001” wc <9.999” wc
0.01” wc >10.00” wc
0.001mBar <24.999mBar
0.01mBar >25 mBar
±0.4” wc (±1mBar) ±0.01” wc (±0.03mBar)
±32” wc (±80mBar) ±3% reading
Includes

- C157 Analyzer
- Flue Probe
- Smoke Pump Tester
- Smoke Test Paper & Chart
- IR Printer
- (2) K-Type Temp Probes
- (2) Static Pressure Hoses
- (1) True Draft Probe
- Gas Tap and Hose
- AC Adapter/Charger
- Hard Case
- (2) Printer Paper Rolls
- (2) Particle Filters
- Batteries
- Quick Start Guide
- Owners Manual

Shipping

Free Shipping

Returns

Our policy lasts 30 days. If 30 days have gone by since you received purchase, unfortunately we can’t offer you a refund or exchange.

To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.