Description
Testo 330-1G LL Combustion Analyzer with Case & Printer
The Testo 330-1G LL is combustion analysis without confusion. Redesigned with a full color graphic display, the 330-1G LL combustion analyzer allows the user to visualize the measurement data graphically without watching numerical values. Self-explanatory graphic curves, as well as easy to understand symbols and a clear color display, ease the understanding of the measurement data considerably, showing the user where they are at, and a trend line of where they are headed during the adjustment process.
Thumb symbols instantly identify system status of O2 and CO concentrations in the green zone (safe & efficient), confirming operation falls within the manufacturers guidelines.
User configuration allows the display of 4- to 8-lines as numerical values and 4 measurement values simultaneously in a line-graph display. This feature shows trends that may be compromising safe operation or fuel combustion, such as depressurization of the combustion air zone, loss of draft, or fluctuating O2 due to potential heat exchanger failure.
The Testo 330-1G LL also offers the option to be equipped with Bluetooth capabilities to allow wireless connection to a PC, printer, or Android device. TestoDroid is the free Testo Android app which allows data measurements to be live streamed and stored to any android device. TestoDroid also has the ability to start and stop measurements. It gives you the option of viewing the data in a chart, like the one on the Testo, or to produce a graph. The app also provides the option of saving the data not only onto the device, but also saving data on google drive or putting it directly into an email.
Features
- Measures: Temperature, Draft, O2, CO, Efficiency, CO2. With optional probes: Ambient CO, Gas Leakage, Ambient CO2
- 240 x 320 Color graphic display
- Graphic processing of data
- Self diagnostics
- Gas standing pressure test
- User defined fuels
- Logger function for long termmeasurement
- Long life sensors (up to 6 years CO & O2)
- Reduced cost of ownership
- Memory up to 500,000 readings
- USB interface for data readout to PC
- Optional Bluetooth Connectivity to other devices
- Over 10 hourscontinuous operation
- 4 year sensor guarantee
Warranty Information
- Instrument/probe/gas sensors (O2, CO) 4 years
- NO, COlow sensor 2 years
- Thermocouple and rechargeable battery 1 year
Product Specs
Function | Range | Resolution | Accuracy |
O₂ | 0 to 21% | 0.1% | ±0.2% |
CO₂ (Calculated) | 0 to CO₂ max (Display range) |
0.1% vol. | ±0.2% vol. |
Ambient CO₂ with Probe 0632 1240 | 0 to 10000 ppm | - | ±(3% + 75 ppm) from 0 to 5000 ppm ±(5% + 150 ppm) from 5000 to 10000 ppm |
CO | 0 to 4000 ppm | 1 ppm | ±20 ppm from 0 to 400 ppm ±5% from 400 to 1000 ppm ±10% from 1000 to 4000 ppm |
CO (H₂-comp) | 0 to 8000 ppm | 1 ppm | ±10 ppm or ±10% from 0 to 200 ppm ±20 ppm or ±5% from 200 to 2000 ppm ±10% from 2000 to 8000 ppm |
CO Low | 0 to 500 ppm | 0.1 ppm | ±2 ppm from 0 to 40 ppm ±5% for rest of range |
Ambient CO with Flue Gas Probe | 0 to 2000 ppm | 1 ppm | ±10 ppm from 0 to 100 ppm ±10% from 100 to 2000 ppm |
Ambient CO with Probe 0632 3331 | 0 to 500 ppm | 1 ppm | ±5 ppm from 0 to 100 ppm ±5% for rest of range |
Draft | -10 to 40 hPa | 0.01 hPa | ±0.02 hPa or ±5% from -0.5 to 0.6 hPa ±0.03 hPa from 0.6 to 3 hPa ±1.5% from 3 to 40 hPa |
Pressure | 0 to 300 hPa | 0.1 hPa | ±0.5 hPa from 0 to 50 hPa ±1% from 50 to 100 hPa ±1.5% for rest of range |
Temperature | -40 to 2192 °F (-40 to 1200 °C) |
0.1 °F/°C 1 °F/°C |
±0.9 °F (0.5 °C) from 32 to 212 °F (0 to 100 °C) ±0.5% for rest of range |
Efficiency Net | 0 to 120% | 0.1% | - |
Flue Gas Loss | 0 to 99.9% | 0.1% | - |
Gas Leak Testing with Probe 0632 3330 | 0 to 10000 ppm CH₄/C₃H₈ |
- | - |
NO (Optional) | 0 to 3000 ppm | 1 ppm | ±2 ppm from 0 to 40 ppm ±5% from 40 to 2000 ppm ±10% from 2000 to 3000 ppm |
NO Low (Optional) | 0 to 300 ppm | 1 ppm | ±2 ppm from 0 to 40 ±5% for rest of range |
General Specifications | |||
Memory | 500,000 readings | ||
Display | Color display, 240 x 320 pixels | ||
Operating Temperature | 23 to 113 °F (-5 to 45 °C) @ 0 to 90% RH, non-condensing | ||
Storage Temperature | -4 to 122 °F (-20 to 50 °C)@ 0 to 90% RH, non-condensing | ||
Power Supply | 3.7V rechargeable battery or AC adapter | ||
Battery Life | 6 hours (pump on, 68 °F (20 °C) ambient temperature) | ||
Charge Time | Approx. 5 to 6 hours | ||
Ingress Protection | IP40 | ||
Dimensions | 10.6 x 3.55 x 2.6 in (270 x 90 x 65 mm) | ||
Weight | 21.2 oz (600 g) excluding battery |
Includes
- 12 inch flue gas probe, 1/4 inch diameter, w/ 7 ft hose
- Power supply / recharger (North American cord)
- Particle filters - pack of 10
- IR printer
- Thermal printer paper - 6 rolls (10 year legibility)
- Standard case
Shipping
Free Shipping
Returns
Our policy lasts 30 days. If 30 days have gone by since you received purchase, unfortunately we can’t offer you a refund or exchange.
To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.